Displaying report 1-1 of 1.
Reports until 13:29, Tuesday 30 August 2016
H1 General (SUS)
edmond.merilh@LIGO.ORG - posted 13:29, Tuesday 30 August 2016 - last comment - 12:08, Wednesday 31 August 2016(29386)
ETMY OpLev maintenance

This morning at about 16:00UTC I made some adjustment to ETMY oplev as per WP #6123. I've included some photos of a 5day trend as well as a before and after 5 the AA reset. THe output power was increased by 7mV in an attempt to stop glitches. I don't know if the after reset pic is of any use as the suspension hadn't quite settled down.

Images attached to this report
Comments related to this report
jason.oberling@LIGO.ORG - 12:08, Wednesday 31 August 2016 (29413)

1st attachment is a 1.5-day second trend of the ETMy SUM signal.  It is clearly seen that after Ed reset the oplev AA chassis the signal is much quieter.  Residual noise is likely caused by laser glitches.  The glitching has improved with Ed's adjustment of the laser power, but it appears a further tweak is necessary (see the last 2 attachments; 1st is before adjustment, 2nd is after.  Taken from the DetChar summary pages.).

Images attached to this comment
Displaying report 1-1 of 1.