pt120 higher than expected
Expecting PT120 to be 3 x 10-9 torr -> Don't see logged activity to explain -> am on road and not able to trend data etc.
Comments related to this report
john.worden@LIGO.ORG - 21:44, Tuesday 30 August 2016 (29401)

Probably gauge problem since 114 did not follow.

Images attached to this comment
john.worden@LIGO.ORG - 21:53, Tuesday 30 August 2016 (29402)

Some more gauges - 

Images attached to this comment
chandra.romel@LIGO.ORG - 10:37, Thursday 01 September 2016 (29435)
Pressure change was due to incorrect wiring of PT-120 during Beckhoff transition and was brought to light when Gerardo incorporated signal wiring for AIPs and needed to turn off PT180 this week. Pressure reading now is correct (and the same as it was in Q2 2016). We should check other gauges to be sure they are wired properly and reading correct pressures. 

Wearing laser safety glasses contributes to issues like this because visibility is compromised.