HAM-ISI Unit #5 - Assembly Validation Report Ready

The report for HAM-ISI Unit #5 - Assembly Validation is now posted under the DCC for validation.

This unit was tested at the begining of the month with testing horizontal GS13s (alog #2802). These testing pods were replaced with production pods. All tests involving GS13s were performed again this week. This report is now waiting for approval. This Unit will then be our second HAM-ISI coming out of the staging building with a full set of production GS13s (the first one was HAM-ISI Unit #4).

Reports regading the Assembly validation of previous units at LHO are also available on the DCC:

HAM-ISI Unit #1 - Assembly Validation
HAM-ISI Unit #2 - Assembly Validation
HAM-ISI Unit #3 - Assembly Validation
HAM-ISI Unit #4 - Assembly Validation

 
Reports regading the Chamber Side testing of other units at LHO are also available on the DCC:
HAM-ISI Unit #4 (HAM3, or HAM2 chamber)
Comments related to this report
hugo.paris@LIGO.ORG - 10:56, Tuesday 29 May 2012 (2967)

This testing report is now approved