Updated and restarted h0vaclx and h0vacly
WP 6132

I updated the code from svn to add the new beam tube annulus ion pumps (LX IBM 122, LX OBM 136, LY IBM 192, LY OBM 196). It turned out that I connected the LX annulus ion pumps to the old PT110 channels instead of the old PT170 channels and thus the readings for these are currently wrong (the signal cables were landed on the old PT170 channels). This has been fixed in svn but h0vaclx has to be updated and restarted again at some later opportunity.

As expected the restart tripped the ITM ESD high voltages. Filiberto reset them.

I burtrestored both IOCs to 8 am. Dave added the channels to the DAQ.

I'm leaving the work permit open until h0vaclx is updated and restarted again.