Reports until 19:06, Friday 09 September 2016
H1 TCS
kiwamu.izumi@LIGO.ORG - posted 19:06, Friday 09 September 2016 - last comment - 17:38, Saturday 10 September 2016(29585)
TCS tuning test at 20 and 40 W

Stefan, Matt, Kiwamu,

This is a quick note. We started another TCS test in this afternoon with the new ring heater setting (RHX = 0.5 W and RHY = 1.5 W, 29557).

With a 20 W interferometer, the CO2 settings that balances the 45 MHz upper and lower sidebands were found to be at almost where we thought it should be. Then we increased the PSL power to 40 W to study the interferometer absorption as a function of the PSL power. With the sideband imbalance adjusted, the lock seems more stable at 40 W.

 

[good values that balances the 45 MHz sidebands]

These settings seem to give us a small imbalance within 10%. Also, lock acquisition was done with [CO2X, CO2Y] = [500 mW, 700 mW] in which I did not adjust the differential CO2 settings.

By the way, the attached trends show how the aberration changed when we went from 20 to 40 W. Notice that ITMY show relatively high aberration values (e.g. cylindrical, coma, spherical aberration) compared to the ones for ITMX. The last attachment is a StripTool showing the HWS outputs. A jump in the middle is due to us increasing the PSL from 20 to 40 W. After we sat on 40 W for approximately 1 hour, we started decreasing the common TCS and kept adjusting the differential CO2.

Images attached to this report
Comments related to this report
matthew.evans@LIGO.ORG - 17:38, Saturday 10 September 2016 (29589)

We subsequently went to 50W and saw little change.  There was some more uncompensated lensing, but it was not a big effect and the lock remained stable.  We had a little trouble with PIs (mostly self-inflicted due to PLL testing) which caused a brief retreat to 35W, but we quickly returned to 50W.  After about 30 minutes at 50W, we started the transition to low-noise.  This broke the lock, apparently during the feed-forward turn on and due to a ASC-SRC1_YAW run-away.  To be investigated...

Images attached to this comment