PI damping model update (h1susprocpi, work permit 6149)

Matt, Terra (in spirit)

I have updated the h1susprocpi model to fix a few minor problems.

In terms of channel names, the impact of this model change should only be the addition of AMP_PRE_OFFSET and AMP_POST_OFFSET.  I have only updated the models (i.e., I have not rebuilt the FE code, etc.).  The corresponding work permit is 6149, and this change should go in with the next DAQ restart, or on Tuesday (which ever comes first).