Displaying report 1-1 of 1.
Reports until 01:20, Tuesday 13 September 2016
H1 ISC
terra.hardwick@LIGO.ORG - posted 01:20, Tuesday 13 September 2016 (29645)
New ETMX PI 15007 Hz

Tonight we saw ETMX 15007 Hz MODE 18 ring up almost immediately upon increasing power to 50 W. It damped with no problems with -1k damping gain, no phase. Active damping for this mode has been added to the SUS_PI guardian. First attachment shows ring up and subsequent damping. 

Not sure why this mode didn't ring up last night; the only thing that's different is that last night Kiwamu babysat the ITMX CO2 laser power. Second attachment shows last night, third attachment shows tonight. Upon arriving at 50 W last night, the CO2 power was ~0.08 W, versus tonight the power was ~0.39 W. However, SRC and PRC gouy phases are both very similar at that time.  

Images attached to this report
Displaying report 1-1 of 1.