J. Garcia, J. Kissel Jeff launched a set of TFs on ETMY before heading out on Friday, just after Team TMS finished up in chamber, and Travis had set ETMY's EQ Stops to pump-down ready ~0.75 mm distance to confirm that the SUS was still free. Attached are the results. Everything looks just as it did before, matches up with other SUS's up its type, and agrees well with the model. Things are looking good, couldn't ask fo mo betta!
The data was taken by the template collection script /ligo/svncommon/SusSVN/sus/trunk/QUAD/H2/ETMY/collectTF_H2SUSETMY_M0R0_allDoFs.m which saved the data to the following raw files M0 Raw Data (and diary of workspace): /ligo/svncommon/SusSVN/sus/trunk/QUAD/H2/ETMY/SAGM0/Data/2012-05-25_H2SUSETMY_M0_0p01to50Hz_allDOFs_DAMPSOFF_tf.mat /ligo/svncommon/SusSVN/sus/trunk/QUAD/H2/ETMY/SAGM0/Data/2012-05-25_H2SUSETMY_M0_0p01to50Hz_allDOFs_DAMPSOFF_tf_diary.txt R0 Raw Data (and diary of workspace): /ligo/svncommon/SusSVN/sus/trunk/QUAD/H2/ETMY/SAGR0/Data/2012-05-25_H2SUSETMY_R0_0p01to50Hz_allDOFs_DAMPSOFF_tf.mat /ligo/svncommon/SusSVN/sus/trunk/QUAD/H2/ETMY/SAGR0/Data/2012-05-25_H2SUSETMY_R0_0p01to50Hz_allDOFs_DAMPSOFF_tf_diary.txt These were processed and plotted using /ligo/svncommon/SusSVN/sus/trunk/QUAD/Common/MatlabTools/plotquad_matlabtfs.m which produced the 2nd and 3rd attached set of detail plots, as well as the usual generic data file: /ligo/svncommon/SusSVN/sus/trunk/QUAD/H2/ETMY/SAGM0/Results/2012-05-25_H2SUSETMY_M0_fiber_model_MATTF.mat /ligo/svncommon/SusSVN/sus/trunk/QUAD/H2/ETMY/SAGR0/Results/2012-05-25_H2SUSETMY_R0_erm_model_MATTF.mat This data set has been added to the list of measurements and plotted against other selected measured measurements in /ligo/svncommon/SusSVN/sus/trunk/QUAD/Common/MatlabTools/plotallquad_dtttfs.m which generates the first attachment's collection of plots.