Displaying report 1-1 of 1.
Reports until 14:05, Wednesday 14 September 2016
H1 ISC
terra.hardwick@LIGO.ORG - posted 14:05, Wednesday 14 September 2016 - last comment - 18:21, Wednesday 14 September 2016(29702)
ETMY Ring Heater turned off

We turned the ETMY ring heater off (.55 W --> 0 W top and .55 W --> 0 W bottom) at 21:00 UTC. 

Change was made since we seem unable to damp ETMY Mode 27 (18041 Hz). 

Comments related to this report
terra.hardwick@LIGO.ORG - 18:21, Wednesday 14 September 2016 (29708)

Change seems effective. We just had ~2 hour lock during which we passed through the RH change transient peak and all PIs are dampable; we're no longer sitting over the 47kHz mechanical modes that were undampable this morning. We've been slowly changing modes over to PLL damping (as opposed to just static BP + phase filters). The potentially problematic Mode 2 (15520 Hz on ITMX) became unstable during the lock but remained damped with the PLL. We've confirmed that some too-high damping gain, even below ESD saturation values, will indeed make damping efforts ineffective; something along the way must be saturating. Damping using the PLL solves this as it outputs some fixed gain that we can keep below this 'bad' gain level (~30k cts). 