Displaying report 1-1 of 1.
Reports until 11:58, Wednesday 30 May 2012
H1 AOS
jason.oberling@LIGO.ORG - posted 11:58, Wednesday 30 May 2012 (2978)
BSC06 ETMy Pitch Alignment
IAS: J. Oberling
SUS: B. Bland, T. Sadecki
 
We adjusted pitch this morning with no First Contact on the ETMy to correct for the pitch error induced by the First Contact.  The pitch was adjusted to 623 µrad down which is 16 µrad away from our target (639 µrad down) and well within the ±160 µrad spec.