Displaying report 1-1 of 1.
Reports until 17:33, Tuesday 20 September 2016
H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 17:33, Tuesday 20 September 2016 (29852)
tuesday maintenance summary

new h1calcs model WP6174

Jeff, Darkhan, Dave:

new h1calcs model installed. DAQ restart combined this and the last h1psliss changes.

h1psliss model WP6172

Daniel, Keita, Ben, Dave:

h1psliss was restarted several time, first to primarily replace OUTERLOOP with SECONDLOOP naming. Subsequent restart for minor name tweaks. Several DAQ restarts

Clone h1fw1 WP6171

Carlos, Dave

NDS were switch to using h1fw0's frames. h1fw1 was shutdown and its boot disk is being cloned. Due to its size (1TB) this will take overnight.

Reboot h1guardian0

TJ, Dave

We did a reboot of h1guardian0, later attemps to lock the mode cleaner showed connection errors for Beckhoff channels. Running caget on h1guardian0 did get the data, but showned two paths (direct and via epics-gateway). Stop-start of the node did not force the connection. We turned off the gateway (h1slow-h1fe) and rebooted guardian. Some nodes still showed connection errors, again caget connected. Finally we started the gateway and all the connections completed. Need further investigation with Jamie.

h1guardian0 was updated prior to the reboot, we think this may have broken INJ_TRANS node.

TCS CO2 chiler tests

Dave, Nutsinee:

Confirmed that pulling the chiller cable in preparation for a power cycle of h1oaf0 IOChassis trips the CO2 lasers and should not be done.

Remove old PT140 channels from Vacuum Controls WP6166

Patrick, Dave:

After Patrick had made the Beckhoff changes, I imported his latest h0vaclx.ini file into H0EDCU_VAC.ini This went in on later DAQ restart

Add h1fw2's new diag epics channels to DAQ WP6173

Dave:

h1fw2 is running Jonathan's RCG3.2 daqd with improved diagnostics. These additional channels were added to H1EDCU_DAQ.ini and went in on a DAQ restart.

h1susprocpi model

Terra, Dave:

Terra added epics input channels for state definition. Model was changed and DAQ was restarted. Small number of slow channels were added to DAQ.

DAQ restarts

Dave:

Several DAQ restarts during the day to support the above activities. Most went cleanly, two had minor issues

On one I needed to restart the mxstream from both h1pemmx and h1pemmy

On another I need to restart the mxstream on h1sush56

Displaying report 1-1 of 1.