Displaying report 1-1 of 1.
Reports until 14:22, Wednesday 21 September 2016
H1 ISC
sheila.dwyer@LIGO.ORG - posted 14:22, Wednesday 21 September 2016 (29878)
jitter coupling and projection

Here is some of the data from Saturday's jitter injections (29780), plotted differently.  The main point is that we should be able to reduce the yaw jitter coupling by at least a factor of a few, and this should help the DARM spectrum, but not enough to get the noise a factor of 10 belpw the quantum noise with the current level of jitter.  

Images attached to this report