We did a TCS tuning test at 50W starting at 6:56 UTC. The CO2X power was decreased from the nominal 400 mW to 0. During the test, we have monitored the frequency and intensity noise couplings to DARM by injecting broadband noise. I will analyze and post the results tomorrow, but it seems like that a small CO2X value is better fore laser noise couplings.
During the test, we tried to compensate for varing optical gain by changing the CAL-CS sensing gain setting. There was a period where we had a 80 Mpc range which was due to uncompensated change in the optical gain induced by the thermal transient. However, we believe that the range will be better with the fine tuned CO2s. Unfortunately, the laser tripped shortely after the test. We did not get a chance to examine the improvement.