Displaying report 1-1 of 1.
Reports until 13:09, Monday 26 September 2016
H1 DAQ (DAQ)
david.barker@LIGO.ORG - posted 13:09, Monday 26 September 2016 (29981)
State of the DAQ

Summary of LHO DAQ over the past week. Prior to last Tuesday the DAQ had been stable for several weeks. Starting Tuesday evening (9/20) h1fw0 and h1fw1 became slightly unstable. They sometimes reported errors normally associated with QFS file system problems, and h1fw2 (non-QFS) was stable. Thursday luch time we power cycled both Solaris QFS/NFS machines (h1ldasgw0,1) which has helped with QFS issues in the past. After this point fw0 has been stable, fw1 has restarted twice in 4 days, last restart early Friday morning.

All three writers are running RG3.2 code, fw0 and fw1 have identical hardware. Our attempt to clone fw0 from fw1 last week did not work, we may want to try this again since fw0 is still asking for retransmissions and fw1 is not. (fw2 did ask for a moderate number of retransmissions last week, none since then).