Displaying report 1-1 of 1.
Reports until 23:01, Monday 26 September 2016
H1 ISC
jenne.driggers@LIGO.ORG - posted 23:01, Monday 26 September 2016 (29991)
BS alignment cleared more slowly after lockloss

Since we seem to be needing to help the BS's alignment after locklosses, and if left alone the BS drifts in pitch for many minutes after a lockloss from high power, I've modified the filters in the M1 filter bank such that the pitch ASC values get cleared slowly, rather than instantaneously.

Rather than having a pure integrator, I've added a zero to the pole at 0Hz, and another filter with a pole at that zero's freq.  This way, we can toggle the first filter module, and it'll effectively slowly clear the history of the integrator.  Hopefully this will make re-acquiring PRMI / DRMI easier - operators should let me know if they think it helps or hurts relative to the last week or so.