Displaying report 1-1 of 1.
Reports until 11:28, Tuesday 27 September 2016
H1 DetChar
ansel.neunzert@LIGO.ORG - posted 11:28, Tuesday 27 September 2016 - last comment - 10:25, Thursday 25 October 2018(29997)
Comb updates from recent data

This information is based on the cumulative spectrum of recent lock stretches (9/18-9/26, computed from Fscan SFTs with spec_avg_long), plus Fscan magnetometer data.

0.997698 Hz

1.0 Hz

0.5 Hz odd harmonics (AKA 1 Hz with 0.5 Hz offset)

1.0 Hz with 0.998889 offset (new)

0.987987 Hz (new)

Attached plots:

Images attached to this report
Comments related to this report
ansel.neunzert@LIGO.ORG - 11:49, Tuesday 27 September 2016 (30004)

Minor edit: offset on 4th comb mentioned has too many significant figures. Should be rounded to ~0.9989 (+/- 0.0005).

ansel.neunzert@LIGO.ORG - 11:48, Wednesday 28 September 2016 (30047)

Update on the 0.996798 Hz: this comb appears in magnetometer channels between Feb 3rd and 4th*. After looking at the alogs for surrounding date range, Robert suspected the HWS as a potential source. We checked TCS-ITMX_HWS_RCXCLINKSWITCH and saw a switch on, which corresponded neatly with the date of the comb's appearance in magnetometer channels. Robert has also previously noted near-1Hz combs associated with the HWS in the CS. Richard says that the HWS can be placed on a separate power supply in the near future, which will hopefully clear this up.

 

*edit, typed wrong date

Displaying report 1-1 of 1.