Displaying report 1-1 of 1.
Reports until 16:46, Friday 30 September 2016
H1 PSL
edmond.merilh@LIGO.ORG - posted 16:46, Friday 30 September 2016 - last comment - 17:37, Friday 30 September 2016(30118)
PSL tripped off

@ ≈23:45 UTC

Comments related to this report
edmond.merilh@LIGO.ORG - 17:37, Friday 30 September 2016 (30120)

The Diode Chiller was in error - Flow Sensor 1. With Jason's phone guidance I was able to restart the LASER with no issues. The thought is that this is a pre-cursor to a control panel failure on the Diode chiller. I was informed by Jason that there is one on it's way. It should be here some time late next week.