H2 SUS ETMY M0 R0 TFs before BSC 6 chamber close-out
The attached are the latest M0/R0 transfer function measurements on H2SUSETMY taken on the night of 06/02/2012.  Both chains appear to have no sign of rubbing and have most of their resonances coinciding with the predicted model.  The R0 chain appears to have a cross-coupled resonance in the Longitudinal DoF, but otherwise a very clean measurement.  This measurement suggests the top masses on H2SUSETMY are free-swinging without obstructing forces.  H2SUSETMY is ready for the BSC 6 pump-down. 