david.barker@LIGO.ORG - posted 16:48, Monday 04 June 2012 (3031)
More testing on FMY front end
h2susb78 (FMY) remains unstable. We have been making incremental changes to pin down the problem:

Reattached to Dolphin network

only run the IOP model

reseat all ADC/DAC cards

rearrange ADC/DAC cards to LHO CDS standard (ref Rolf's IO Chassis document)

We have been stable for 2.5 hours with the latest configuration: Dolphin attached, IOP model only, LHO-CDS card layout. Will run with this overnight.