In relation to Sheila's investigation on the increased noise in the aux length loops, I ran BruCO on the loop error signals LSC-PRCL_IN1, LSC-SRCL_IN1, LSC-MICH_IN1.
The BruCo report can be found here:
https://ldas-jobs.ligo.caltech.edu/~gabriele.vajente/bruco_srcl_1159781057/
Beside some expected coherences, there are quite some ASC signals that are coherent in the 10 to 100 Hz region. Of course, it might as well be that the angular signals are polluted by the LSC control.
Coherence with IMC WFS below 100Hz is an indication of coherence with HPO jitter. The attached spectra were taking at 22W. Arbitrary units on the PSDs.