Reports until 15:44, Saturday 08 October 2016
H1 ISC (DetChar, ISC)
gabriele.vajente@LIGO.ORG - posted 15:44, Saturday 08 October 2016 - last comment - 15:50, Saturday 08 October 2016(30332)
BruCo scan

A scan of coherences during last night's lock can be found here:

https://ldas-jobs.ligo.caltech.edu/~gabriele.vajente/bruco_1159948817/

Nothing new:

Additional BruCo scans are available for the PRCL and SRCL error signals:

https://ldas-jobs.ligo.caltech.edu/~gabriele.vajente/bruco_prcl_1159948817/

https://ldas-jobs.ligo.caltech.edu/~gabriele.vajente/bruco_srcl_1159948817/

Images attached to this report
Comments related to this report
gabriele.vajente@LIGO.ORG - 15:50, Saturday 08 October 2016 (30333)

Some interesting coherences with SRCL:

  • AS_B_RF45_Q_YAW
  • IMC-WFS_A_I_PIT
  • ASC-PRC2_Y
  • IMC-PWR_IN

The last one is particularly tantalizing...

Images attached to this comment