Displaying report 1-1 of 1.
Reports until 19:55, Sunday 09 October 2016
LHO General
patrick.thomas@LIGO.ORG - posted 19:55, Sunday 09 October 2016 (30361)
PSL tripped, Ops Evening Summary
Corey has cancelled Ed's owl shift and the rest of mine.

23:04 UTC reset HAM2 HEPI watchdog
23:08 UTC reset HAM2 ISI watchdog
23:12 UTC MC locked. Leaving in down state for Robert.
23:19 UTC PSL tripped off.
23:20 UTC Peter to LVEA to remove PSL test equipment
23:27 UTC Peter back
23:30 UTC Peter back to LVEA
23:32 UTC Peter back
23:40 UTC reset noise eater
23:47 UTC taking power to 50W with just IMC locked for Robert.
23:53 UTC Taking power back to 2W
23:54 UTC Attempting to lock
00:23 UTC PRMI not locking. Starting initial alignment.
00:50 UTC Initial alignment done.
00:53 UTC ETMs are misaligned. Taking input power to 50W for Robert.
01:12 UTC Back to 2W. Attempting to lock.
01:28 UTC reset noise eater
01:39 UTC reset noise eater, back to CHECK_IR
01:51 UTC locked on PRMI, adjusted BS and PRM. PRMI to DRMI transition held, but signals in striptool very ratty. Lost lock on TURN_ON_BS_STAGE2.
Not making it through DRMI locked. I'm suspecting the ISS is oscillating.
02:38 UTC PSL tripped off. Just when I got the ISS and FSS relocked (had to turn random knobs and reset the noise eater a number of times).
Displaying report 1-1 of 1.