TCS corner station model change, ready for installation tomorrow

WP 6229,

I have updated the TCS corner station model (h1tcscs.mdl). I confirmed that the model comiples without an error. The model is ready for installation tomorrow. The model change includes the followings.

The first item is described in T1600451 in detail. The second point is something we newly implemented today in order to get rid of two paricular ezcaread blocks which had been referencing channels that are in the same front end model. To improve this self-referencing situation, we modified TCS_MASTER.mdl so that the TCS block returns the CO2 power as an output. See the attached screenshot for how we routing the CO2 powers to the SIM block.

Images attached to this report
Comments related to this report
kiwamu.izumi@LIGO.ORG - 18:38, Tuesday 11 October 2016 (30430)

This is now installed. See 30429. The filters for the new channels were set by running the code attached to T1600451-v2. The SDF is also updated.