At the request of DetChar, I have reviewed the LHO PSL ODC thresholds for relevancy now that the HPO is operating. The threshold for Bit 12 (PMC Transmission Limit OK) was still set to 11.5W, which was ~50% of the PMC transmitted power during O1 but is now too low for an operational HPO. Keeping the 50% of output intact, I changed the threshold to 50W; I chose 50W as that is roughly 50% of our current 101W transmitted by the PMC. I accepted the change in the PSL PMC SDF.
This completes WP #6243.