Displaying report 1-1 of 1.
Reports until 12:44, Tuesday 11 October 2016
H1 CAL (CAL, CDS)
darkhan.tuyenbayev@LIGO.ORG - posted 12:44, Tuesday 11 October 2016 - last comment - 13:32, Tuesday 11 October 2016(30411)
Applied the CAL-CS model modifications from LLO

J. Betzwieser, D. Barker, D. Tuyenbayev,

Overview

Updated the h1calcs model to include modifications from LLO, restarted the DAQ system (LHO WP #6238). Now H1 and L1 are running the same version of the CAL-CS model.

Details

After the DAQ restart the coherence calculation settings were changed to:

Number of averages: H1:CAL-CS_TDEP_COH_BUFFER_SIZE 13
Seconds between averages: H1:CAL-CS_TDEP_COH_STRIDE 10

The new CTRL_DELAYfilter is currently empty (unused), and the DELAY_CYCLES (ring buffer / integer delay cycles) is set to 7.

The synchronized oscillators in the CAL-CS time-dependent parameter and coherence calculations were restarted manually. This is a necessary step to get correct phases in the oscillators after a model restart (a bug is described in LHO alog 30220).

Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 13:32, Tuesday 11 October 2016 (30416)
I've gone into the SDF system and made sure to initialize/accept the new settings for the CTRL_DELAY bank. Thanks for getting this together gents!
Images attached to this comment
Displaying report 1-1 of 1.