Reports until 22:51, Tuesday 05 June 2012
H1 CDS
david.barker@LIGO.ORG - posted 22:51, Tuesday 05 June 2012 (3042)
New SEI and SUS front ends for HAM2,3 started
I built the IOP models for the following front ends: h1seih16, h1seih23, h1sush2a, h1sush2b. Unfortunately when starting these new front ends, the DAQ data from the PSL system was corrupted for several minutes at a time until we restored the H1 DAQ. For tonight we have turned off all the new front ends and are just running the h1psl0 system on H1. Only the PSL DAQ data was corrupted, the front end models themselves were not affected.

The IO Chassis for these front ends are being constructed in the H1 EE room. A timing fanout was installed which runs off the new H1 timing master in the MSR (h1psl0 still runs from the H2 master).