Reports until 13:06, Wednesday 12 October 2016
H1 PSL
jenne.driggers@LIGO.ORG - posted 13:06, Wednesday 12 October 2016 - last comment - 21:33, Wednesday 12 October 2016(30458)
Tweaked PSL rotation stage calibration

[Jenne, Cheryl, Nutsinee]

We tweaked the calibration of the PSL rotation stage, which hadn't been done since the power incident on the rotation stage was adjusted about a week ago.  Now hopefully a 50W request will give us 50W, rather than some higher value.  Nutsinee has her script ready for next time, so we can try doing it automatically rather than by hand.

Non-image files attached to this report
Comments related to this report
jenne.driggers@LIGO.ORG - 21:33, Wednesday 12 October 2016 (30479)

I have written a fitting script for PSL rotation stage calibration, and put it in ...../userapps/psl/h1/scripts/RotationStage/

First, run Nutsinee's script MoveRotationStage.py, which will move the rotation stage from -90deg to +90deg, in 5 degree steps, and record the measured angle and the power at the PSL periscope to a text file.

Then with Matlab, run CalibRotStage.m.  This will load the data, calibrate it, and give you a plot with the fitted calibration parameters in the legend. 

Finally, move those values to the PSL rotation stage's calibration screen. 

Unfortunately though, when we use the LASER_PWR guardian to request 50W, we only get about 48W.  This was true earlier with my hand-tuned calibration, as well as with the fits.  This is something that could be looked into.

Images attached to this comment
Non-image files attached to this comment