issues getting here:
REFL WFS centering not coming on in Inital alignment for PRC and SRC, so in both cases those didn't complete until engaged by hand (guardian?)
POPA OFFSETS - Evan looks at these - not sure they're OK but in the end they seem to work
ASC - Evan toggled PRC1_P on and off (3 seconds each) to save the lock and also allow PRC1 P to converge
POPA sum got noisy in ENGAGE SOFT LOOPS until I engaged the CHARD offset of 0.1 by hand in Engage Soft Loops, then the signal improved
I set the ramp on CSOFT to 120 seconds, and at 120 seconds there's a kick that can be seen on CSOFT_P
PI mode 26 rang up and did a bouncing thing until I lowered the gain by half from -5000 to -2500, and then tuned the phase
REFL WFS centering not coming on in Inital alignment for PRC and SRC, so in both cases those didn't complete until engaged by hand (guardian?)
POPA OFFSETS - Evan looks at these - not sure they're OK but in the end they seem to work
ASC - Evan toggled PRC1_P on and off (3 seconds each) to save the lock and also allow PRC1 P to converge
POPA sum got noisy in ENGAGE SOFT LOOPS until I engaged the CHARD offset of 0.1 by hand in Engage Soft Loops, then the signal improved
I set the ramp on CSOFT to 120 seconds, and at 120 seconds there's a kick that can be seen on CSOFT_P
PI mode 26 rang up and did a bouncing thing until I lowered the gain by half from -5000 to -2500, and then tuned the phase