Reports until 14:47, Thursday 13 October 2016
H1 ISC (ISC)
gabriele.vajente@LIGO.ORG - posted 14:47, Thursday 13 October 2016 - last comment - 16:48, Thursday 13 October 2016(30508)
Alignment vs jitter noise

In brief, no success. In details, here are some alignment tweaks trief over the last couple of days:

The decrease of range in the last lock was due to a misalignment of the SRM.

Comments related to this report
daniel.sigg@LIGO.ORG - 16:36, Thursday 13 October 2016 (30511)

Can we roughly quantify this in m/rtHz/rad?

gabriele.vajente@LIGO.ORG - 16:48, Thursday 13 October 2016 (30512)

Moving SRM by ~20 urad reduces the noise by a factor ~2

A bit more like a factor 3 of noise reduction when moving IMC_DOF_1_P with an offset of 400, don't know the calibration