Displaying report 1-1 of 1.
Reports until 00:01, Monday 17 October 2016
H1 General
jeffrey.bartlett@LIGO.ORG - posted 00:01, Monday 17 October 2016 (30580)
Ops Evening Shift Summary
Ops Shift Log: 10/16/2016, Evening Shift 23:00 – 07:00 (16:00 - 00:00) Time -  UTC (PT)
State of H1: IFO is unlocked.
Intent Bit: N/A
Wind: Light Breeze (4-7mph)
0.03 – 0.1Hz: All 0.09um/s
0.1 – 0.3Hz: All around 0.6um/s
Outgoing Operator: TJ
Incoming Operator: Patrick
 
Activity Log: Time - UTC (PT)
22:50 (15:50) Checked TCS Chillers – TCS-X OK; Add 200ml to TSC-Y (6.5 to 8.5)
23:00 (16:00) Take over from TJ
23:10 (16:10) Initial Alignment and relocking
00:50 (17:50) Evan – Going into LVEA 
00:55 (17:55) Evan – Out of LVEA
01:32 (18:02) Locked at DC_READOUT
01:35 (18:35) Evan - Measuring RF modulation depth
03:02 (20:02) Locked at NOMINAL_LOW_NOISE	, at 44.5W, 64.7MPc
03:55 (20:55) Sheila – Going into the LVEA for CARM Loops
04:24 (21:24) Sheila – Out of the LVEA
07:00 (00:00) Turn over to Patrick

Shift Details:
Support: Evan                 
Shift Summary:  IFO broke lock after a 9.5-hour stretch. Having trouble getting past PRMI and DRMI, and the X and Y arms did not look that good. Run Initial Alignment. The alignment was having trouble getting PRM to converge. Tweaked up the PRM alignment, and completed Initial Alignment. After a couple of tries locked at DC_READOUT. Turn over to Evan for commissioning.

Go up to high power; Shelia and Evan commissioning.

Second half of shift mostly spent trying to relock. Damping Roll and Bounce modes that were ringing up. Also had issues with the ISS Autolock oscillating and the FSS PZT MON saturating.  At the end of the shift a magnitude 6.9 EQ hit, bringing up the seismic to near 1.1um/s. Put on the SEI_CONFIG in EARTH_QUAKE_V2, but to no avail. Set the IFO to DOWN, and turning over to Patrick.  

Displaying report 1-1 of 1.