Displaying report 1-1 of 1.
Reports until 07:59, Monday 17 October 2016
LHO General
patrick.thomas@LIGO.ORG - posted 07:59, Monday 17 October 2016 (30582)
Ops Owl Summary
Left in down while the earthquake subsided. Had a hard time getting through an initial alignment. The IMC kept losing lock in INPUT_ALIGN and PRM_ALIGN. Not certain what finally allowed it to stay locked long enough to get through these states. ISS and FSS still losing lock, but recovered on their own each time. IFO is in NLN but range has been dropping steadily.

Starting shift with 6.9 magnitude earthquake reported 78km WNW of Kandrian, Papua New Guinea at 06:14:58 UTC. Jeff B. has put ISC_LOCK in down.
09:57 UTC Earthquake has subsided but wind is increasing
10:00 UTC Starting attempting to lock. Changed ISI config from EARTH_QUAKE_V2 to WINDY.
10:04 UTC Paused at LOCKING_ARMS_GREEN. Both are less than 1 on WFS. X is kind of jittery. No apparent glitches of ALS PDH control signals. Node is still waiting for arms to settle, won't proceed to locking ALS. Reluctantly moving TMS Pitch. Started with TMSX 67.8 and TMSY 127.5. This cleared the waiting for arms to settle message and allowed moving on.
10:25 UTC Lock loss waiting for DRMI ASC to converge
10:44 UTC Lock loss right after CARM_5PM. ISS in oscillation. Recovered on its own after about 140 sec.
10:48 UTC Lock loss during LOCKING_ALS.
10:51 UTC Lock loss during LOCKING_ALS.
11:03 UTC Check IR signals not stable. Starting to hear wind on building.
11:07 UTC Put in down
11:12 UTC Try locking again
11:27 UTC Lock loss at CARM_5PM
11:28 UTC Put in down
11:45 UTC Starting initial alignment
ALS X arm randomly dropping out of lock. MC not stable on input align. Put IMC_LOCK to down. IMC_LOCK is in down, but IMC still seems to be trying to lock?
12:30 UTC Finally got to INPUT_ALIGN. Waiting for ASC convergence.
Initial alignment past locking arms green seems to make IMC quite unstable.
12:54 UTC Initial alignment done
13:25 UTC NLN
Displaying report 1-1 of 1.