Displaying report 1-1 of 1.
Reports until 11:15, Monday 17 October 2016
H1 SEI
jim.warner@LIGO.ORG - posted 11:15, Monday 17 October 2016 (30592)
Some wind fence pics

I went to EX this morning to check on the wind fence after Friday's wind storm. The fence is still there, intact, and hasn't accumulated any tumbleweeds, which is one of the concerns Robert had about a fence. However, a couple of the posts have been twisted, probably by the wind load and moisture, and all of the poured concrete footings have started creeping in the sand. I dont think there is any danger of the fence collapsing, yet, but I'll keep an eye on this.

Attached photos are: a picture of the total coverage from a month or two back (this hasn't changed), a picture showing the worst twisted post (this is new, I didn't notice this the last time I looked) and a picture of the gap in the sand around one of the footings (not new, but it's been getting bigger).

Images attached to this report