Displaying report 1-1 of 1.
Reports until 10:32, Thursday 20 October 2016
H1 PSL
peter.king@LIGO.ORG - posted 10:32, Thursday 20 October 2016 - last comment - 12:44, Thursday 20 October 2016(30689)
pre-modecleaner high voltage measurements
Measurements of the pre-modecleaner high voltage monitor with the pre-modecleaner locked and
unlocked (see plot legend).
Images attached to this report
Comments related to this report
peter.king@LIGO.ORG - 12:44, Thursday 20 October 2016 (30696)
Turning on/off the make up air fan does not affect the measurement(s).  red trace: off, blue trace: on.
By "on" the make up air fan was at its commissioning mode speed of 20%.
Images attached to this comment