edmond.merilh@LIGO.ORG - posted 16:07, Saturday 22 October 2016 - last comment - 19:02, Saturday 22 October 2016(30751)
Shift Summary -Day
The day started with not much hope of taming PI modes.
After deciding to do an initial alignment, it was discovered after Sheila finally arrived that SR2 had been knocked off alignment so much that SRC_ALIGN kept shaking and tripping watchdogs in HAM5 when trying to center.
Terra had the answers to the PI issue regarding bandpass filters aimed in the wrong range but there was no communication about it during the night.
Further difficulties locking PRMI/DRMI were addressed after Stefan got here. Mainly gains and some alignment.
Sheila taking data from new TCS adjustments
the remainder of the shift was an occassional exercise in damping PI modes.
Mike Landry stole someone's lunch.
Comments related to this report
terra.hardwick@LIGO.ORG - 16:31, Saturday 22 October 2016 (30753)
My earlier comment assumption was correct: during the settling of the recent ring heater changes, Mode26 had shifted outside of the usual guardian-controlled bandpasses; an already existing filter needed to be turned on. After this, we powered up and damped with no problems. Locked for 2.5 hours at this point needing only normal phase changes. I walked Ed through how to check on this and change the filter, but this large of change only occurs after a ring heater change so will not be a normal issue operators need to worry about.
Reminder that I've requested to be called anytime there is a persistant PI problem.
terra.hardwick@LIGO.ORG - 19:02, Saturday 22 October 2016 (30755)
I've added step-by-step instructions for how to attempt to handle this scenerio in the Operator PI Wiki (under 'If a PI seems unresponsive') if for some reason I can't be reached. PI Wiki can also be opened from PI medm screen. Working on automating this.
My earlier comment assumption was correct: during the settling of the recent ring heater changes, Mode26 had shifted outside of the usual guardian-controlled bandpasses; an already existing filter needed to be turned on. After this, we powered up and damped with no problems. Locked for 2.5 hours at this point needing only normal phase changes. I walked Ed through how to check on this and change the filter, but this large of change only occurs after a ring heater change so will not be a normal issue operators need to worry about.
Reminder that I've requested to be called anytime there is a persistant PI problem.
I've added step-by-step instructions for how to attempt to handle this scenerio in the Operator PI Wiki (under 'If a PI seems unresponsive') if for some reason I can't be reached. PI Wiki can also be opened from PI medm screen. Working on automating this.