The states are designed for in-lock adjustment of the spot position on PR2 and PR3. It is a guardian implementation of the scripts
/ligo/home/controls/sballmer/20160927/pr2spotmove.py
/ligo/home/controls/sballmer/20160927/pr3spotmove.py
So far, turning the PRC1 ASC loops off has to be done manualy.
Instructions
PR3_SPOT_MOVE:
WFS state: disable the PRC1 loop that ordinarily moves the PRM to center POP_A.
Use the PRM alignment sliders to move the beam spot on PR3. The scrips slaves all other optics in order to avoid taxing the WFS.
PR2_SPOT_MOVE:
WFS state: disable the PRC1 loop that ordinarily moves the PRM to center POP_A
Use the PR3 alignment sliders to move the beam spot on PR2. The scrips slaves all other optics in order to avoid taxing the WFS.
(see also alogs 30030, 28442,28627)