fw0 restart caused fw1 restart on Saturday 22nd October

Here is the sequence of events which happened in the 18:23 minute PDT Sat 22 October

18:23:10 - 18:23:24 h1fw0 asked for data retransmissions
18:23:24 h1fw0 stopped running
18:23:26 - 18:23:36 h1fw1 asked for data retransmissions
18:23:36 h1fw1 stopped running

Having both frame writers down meant we lost three full frames for the GPS times 1161220928, 1161220992, 1161221056

Clearly fixing the retransmission errors will become a higher priority if they are cascaded like this and not random as they have been in the past. Our third frame writer h1fw2 did not crash and could have been used to fill in the gap if it were to be connected to LDAS.