This morning a broad increase in ground motion around 12Hz reduced the range. ISCT1 has a table resonance there so I shook it and noticed that shaking by several times normal produced significant noise (see attached Fig). We switched to REFL B 9I and 45I so that we could close the beam diverter. The coupling went away.
Robert Stefan Jenne Evan