Jenne, Stefan
PRMI and DRMI lock acquisition was very sloppy the last few days, so we actually looked at the fringes, gains, trigger thresholds, etc. A number of tweaks were required:
REFLAIR_A_RF45 PHASE was changed from 142deg to 157 to minimize the I signal bleeding through.
PRMI acquisiton gains: PRCL 16, MICH 2.8
PRMI locked gains: PRCL 8 (nominal UGF 40Hz), MICH 2.8 (nominal UGF 10Hz)
DRMI locked gains: PRCL 8 (nominal UGF 40Hz), MICH 1.4 (nominal UGF 10Hz), SRCL -45 (nominal UGF 70Hz)
DRMI acquisition gains: same as PRMI: PRCL 16, MICH 2.8, and SRCL -30