J. Kissel Integration Issues: 6463, 4694 ECRs: E1600316, E1600028 WP: 6263 I've completed the changes begun this past Friday (LHO aLOG 30728) and Monday (LHO aLOG 30821) by installing and restarting all SUS front-end models this morning. Again, changes are (1) the removal of now-redundant ISI_WIT channel path which projected ISI GS13s to the suspension point basis. These are now computed elsewhere. (2) the revamp of the SUS science frame channel storage; updated to match T1600432 Regarding (1), I've also updated each SUS-type's MEDM overview screens to remove these paths (just an SVN update; thanks Stuart!), and I've resaved and reloaded all SUS safe.snaps in the SDF system to remove these channels which were registering as are no longer found. We need only a DAQ restart, and then (2) takes affect. @Detchar: Please let us know if your down-stream / off-site software has been adversely affected (once maintenance is complete, of course).