Displaying report 1-1 of 1.
Reports until 15:59, Wednesday 26 October 2016
LHO VE
chandra.romel@LIGO.ORG - posted 15:59, Wednesday 26 October 2016 (30905)
CP4 signal noise
As noted yesterday, LLCV and %full at CP4 are noisy (before and after Dewar fill). Things stabilized after I opened the exhaust bypass valve. Today I removed the check valve and closed bypass valve; noise again. Then I installed CP3's check valve; still noisy. So I reinstalled the original check valve and left bypass valve open. Suspect the PID parameters need adjustment. 
Displaying report 1-1 of 1.