A separate input offset has been added to the AC coupling which is before the on-off switch.
We also commissioned the reference servo which automatically zeroes the output offset, when the second loop is off. The bandwidth is about 1/3 Hz. It requires the excitation input switch to be on, so any analog cabling to this input needs to be disconnected.