Reports until 19:22, Friday 28 October 2016
H1 ISC (ISC, OpsInfo, TCS)
kiwamu.izumi@LIGO.ORG - posted 19:22, Friday 28 October 2016 (30974)
TCS long term measurement; no improvement so far, we should do differential next

Jeff B, Cheryl, Travis and Kiwamu,

In the past two days, Jeff, Cheryl and Travis performed a random walk on the CO2 settings for me (30920 and comments therein). I don't see significant change so far. In fact, it might have deteriorated the jitter peaks slightly.

I now ask the operators to perform differential scans instead (e.g. raising only one CO2 at a time).


The motivation was to see if we can exert any kind of effects on the jitter peaks in 200-1000Hz by changing the CO2 settings. Because TCS measurements usually take a long time, I have asked the operators to do some random walk on the TCS settings when possible. So far we have done a common scan (i.e. raising both CO2 powers simultaneously) and I don't see big change in the jitter peaks in 200-1000 Hz, in particular the ones at 285, 365 and 620 Hz. The attached shows DARM spectra with different CO2 settings.

These curves correspond to the following time.

As you can see, the ambient noise (most of the time appears to be shot noise) varies depending on the time because some of them overlapped with the active injection tests by Robert. But, this is not something I am looking for. Among the 6 noise curves, the best jitter noise was obtained from 27/10/2016 9:40:00 UTC which is actually before the series of CO2 tests started. So it is possible that the common CO2 may have deteriorated the jitter peaks slightly. We should do a differential scan next.

Images attached to this report