Displaying report 1-1 of 1.
Reports until 20:06, Friday 28 October 2016
H1 GRD (INJ)
evan.goetz@LIGO.ORG - posted 20:06, Friday 28 October 2016 - last comment - 09:00, Saturday 29 October 2016(30975)
Gain of PINJX_TRANSIENT filter bank
I think that the nominal setting of the CAL-PINJX_TRANSIENT filter bank gain is supposed to be zero. When a transient injection is imminent, then the gain is ramped to 1.0, the injection happens, and then the gain is ramped to zero. However, the SDF safe set point is 1.0. Therefore, I am setting the gain to 0 and accepting the change in the SDF safe file.
Comments related to this report
keith.thorne@LIGO.ORG - 06:26, Saturday 29 October 2016 (30986)CAL, GRD
The existing code in the INJ_TRANS Guardian script does indeed do this.  
david.barker@LIGO.ORG - 09:00, Saturday 29 October 2016 (30992)

if guardian is controlling the gain, perhaps sdf shouldn't be monitoring it.

Displaying report 1-1 of 1.