Displaying report 1-1 of 1.
Reports until 08:49, Monday 31 October 2016
H1 CAL (CAL, DetChar, ISC, OpsInfo)
jeffrey.kissel@LIGO.ORG - posted 08:49, Monday 31 October 2016 (31024)
PCALX Roaming Calibration Line Frequency Changed to 1001.3
J. Kissel for S. Karki

I've moved the roaming high frequency calibration line driven by PCAL X from 1501.3 to 1001.3 Hz at Oct 31 2016 15:44:29 UTC (1161963886, 08:44:29 PDT). Note, O2 reference measurements for PCALX will be taken tomorrow, we should be sure to scale any results to those measurements.

Here's the status: 
Frequency    Planned Amplitude        Planned Duration      Actual Amplitude    Start Time                 Stop Time                    Achieved Duration
(Hz)         (ct)                     (hh:mm)                   (ct)               (UTC)                    (UTC)                         (hh:mm)
---------------------------------------------------------------------------------------------------------------------------------------------------------
1001.3       35k                      02:00                   39322.0           Oct 31 2016 15:44:29 UTC
1501.3       35k                      02:00                   39322.0           Oct 24 2016 15:26:57 UTC    Oct 31 2016 15:44:29 UTC      ~week @ 25 W
2001.3       35k                      02:00                   39322.0           Oct 17 2016 21:22:03 UTC    Oct 24 2016 15:26:57 UTC      several days (at both 50W and 25 W)
2501.3       35k                      05:00                   39322.0           Oct 12 2016 03:20:41 UTC    Oct 17 2016 21:22:03 UTC      days     @ 50 W
3001.3       35k                      05:00                   39322.0           Oct 06 2016 18:39:26 UTC    Oct 12 2016 03:20:41 UTC      days     @ 50 W
3501.3       35k                      05:00                   39322.0           Jul 06 2016 18:56:13 UTC    Oct 06 2016 18:39:26 UTC      months   @ 50 W
4001.3       40k                      10:00
4301.3       40k                      10:00       
4501.3       40k                      10:00
4801.3       40k                      10:00  
5001.3       40k                      10:00
Images attached to this report