Displaying report 1-1 of 1.
Reports until 00:18, Tuesday 01 November 2016
LHO General (OpsInfo)
corey.gray@LIGO.ORG - posted 00:18, Tuesday 01 November 2016 (31044)
OPS Eve Shift Summary

TITLE: 10/31 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Wind
INCOMING OPERATOR: Nutsinee
SHIFT SUMMARY:

Had some trouble with the MC.  Sometimes Clearing History (ASC WFS) would help.  Another time FSS was oscillating, so the Fast Gain was ramped down to it's lowest value and returned to 9.0.  (Sheila mentioned both of these to me.)

For first attempts at locking, simply tried to lock (no initial alignment), and would lock DRMI, but it would drop out shortly after.  Jenne mentioned going to LOCK_DRMI_1F and then looking at ASC ERROR signals on striptool & tweak optics for signals which have big ERROR signals.

LOG:

Displaying report 1-1 of 1.