Mid-Shift Summary - Eve
After PSL team came out of the enclosure Jenne and I began initial alignment procedure
Jenne tagged out and Jeff K joined me at ops. After a little difficulty with SRC. we began full locking only to break at PREP_TR_CARM
Stefan found some bad offsets in the TR_CARM step, so he created a new step to mitigate.
Locking made it to ENGAGE_ASC_PART2, at which time Sheila concluded that the arm alignment needed some attention.
Another initial alignment is being done at this time.
DMT seems to be locked-up
Environmentally quiet with uSei trending back downward