model restarts logged for Thu 03/Nov/2016 - Wed 02/Nov/2016 No restarts reported
model restarts logged for Tue 01/Nov/2016
2016_11_01 11:14 h1ioppsl0
2016_11_01 11:14 h1psldbb
2016_11_01 11:14 h1pslfss
2016_11_01 11:14 h1psliss
2016_11_01 11:14 h1pslpmc
2016_11_01 11:23 h1calcs
2016_11_01 11:23 h1iopoaf0
2016_11_01 11:23 h1ioppsl0
2016_11_01 11:23 h1ngn
2016_11_01 11:23 h1oaf
2016_11_01 11:23 h1odcmaster
2016_11_01 11:23 h1pemcs
2016_11_01 11:23 h1psliss
2016_11_01 11:23 h1tcscs
2016_11_01 11:24 h1calcs
2016_11_01 11:24 h1iopasc0
2016_11_01 11:24 h1ioplsc0
2016_11_01 11:24 h1iopoaf0
2016_11_01 11:24 h1iopsusb123
2016_11_01 11:24 h1lscaux
2016_11_01 11:24 h1lsc
2016_11_01 11:24 h1ngn
2016_11_01 11:24 h1oaf
2016_11_01 11:24 h1odcmaster
2016_11_01 11:24 h1omc
2016_11_01 11:24 h1pemcs
2016_11_01 11:24 h1psldbb
2016_11_01 11:24 h1pslfss
2016_11_01 11:24 h1pslpmc
2016_11_01 11:24 h1susitmy
2016_11_01 11:24 h1susprocpi
2016_11_01 11:24 h1tcscs
2016_11_01 11:25 h1ascimc
2016_11_01 11:25 h1asc
2016_11_01 11:25 h1hpiham4
2016_11_01 11:25 h1hpiham5
2016_11_01 11:25 h1iopseih45
2016_11_01 11:25 h1iopsush2a
2016_11_01 11:25 h1iopsush2b
2016_11_01 11:25 h1omcpi
2016_11_01 11:25 h1susauxasc0
2016_11_01 11:25 h1susbs
2016_11_01 11:25 h1sushtts
2016_11_01 11:25 h1susim
2016_11_01 11:25 h1susitmpi
2016_11_01 11:25 h1susitmx
2016_11_01 11:25 h1susmc1
2016_11_01 11:25 h1susmc3
2016_11_01 11:25 h1susprm
2016_11_01 11:27 h1hpiham2
2016_11_01 11:27 h1hpiham3
2016_11_01 11:27 h1iopseih23
2016_11_01 11:27 h1iopsush34
2016_11_01 11:27 h1iopsush56
2016_11_01 11:27 h1isiham2
2016_11_01 11:27 h1isiham3
2016_11_01 11:27 h1isiham4
2016_11_01 11:27 h1isiham5
2016_11_01 11:27 h1susmc2
2016_11_01 11:27 h1suspr2
2016_11_01 11:27 h1suspr3
2016_11_01 11:27 h1sussrm
2016_11_01 11:29 h1hpibs
2016_11_01 11:29 h1hpiitmx
2016_11_01 11:29 h1iopseib1
2016_11_01 11:29 h1iopseib2
2016_11_01 11:29 h1iopseib3
2016_11_01 11:29 h1isibs
2016_11_01 11:29 h1isiitmx
2016_11_01 11:29 h1isiitmy
2016_11_01 11:29 h1susomc
2016_11_01 11:29 h1sussr2
2016_11_01 11:29 h1sussr3
2016_11_01 11:30 h1hpiham1
2016_11_01 11:30 h1hpiham6
2016_11_01 11:30 h1hpiitmy
2016_11_01 11:30 h1iopseih16
2016_11_01 11:30 h1isiham6
2016_11_01 12:05 h1alsex
2016_11_01 12:05 h1calex
2016_11_01 12:05 h1iopiscex
2016_11_01 12:05 h1iscex
2016_11_01 12:05 h1pemex
Tuesday maintenance. ADC addition to h1oaf0 caused dolphin crash in corner station. Rebooted h1iscex to check for ADC offset. No DAQ restarts required.
model restarts logged for Mon 31/Oct/2016 - Fri 28/Oct/2016 No restarts reported