Displaying report 1-1 of 1.
Reports until 12:03, Friday 04 November 2016
H1 PSL
daniel.sigg@LIGO.ORG - posted 12:03, Friday 04 November 2016 - last comment - 09:58, Wednesday 09 November 2016(31203)
Comparison of ISS, ILS and PMC signals

This is a comparison between the ISS, ILS and PMC signals before (REF traces) and after the changes in the electroncis and the modulation depth, see 31095.

A few observations:

Non-image files attached to this report
Comments related to this report
daniel.sigg@LIGO.ORG - 13:28, Friday 04 November 2016 (31205)

A better plot showing the relationship between the ILS and PMC mixer and HVMon signals.

Non-image files attached to this comment
daniel.sigg@LIGO.ORG - 15:23, Friday 04 November 2016 (31211)

Reducing the ILS gain by 16 dB increases the noise seen by the PMC by the same amount below 1 kHz. This change reduced the ILS ugf from ~10 kHz down to ~1 kHz.

Non-image files attached to this comment
daniel.sigg@LIGO.ORG - 09:58, Wednesday 09 November 2016 (31355)

PMC and HPO PZT characterization/calibration

The PMC PZT is decribed in alog 30729:

  • Model: PI PAHH-0013
  • Capacitance: 63 nF
  • Travel: 4 µm/kV
  • Series resistor: 3.3 kΩ
  • Pole: ~770 Hz.

The ILS PZT is

  • Capacitance: 120 nF
  • Travel: 15 µm/kV
  • Series resistor: 3.3 kΩ
  • Pole: ~400 Hz.
Displaying report 1-1 of 1.