TITLE: 11/06 Owl Shift: 08:00-16:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Unknown
INCOMING OPERATOR: Corey
SHIFT SUMMARY: The big news for the shift is alog31249 ESD HV power suppy is having some issues, but Richard will be coming out to the site soonish to fix it. Aside from that, the ITMY is still swinging after locklosses, still havent found a good way to damp it faster. Richard got the power supply going again. Relocking now. Turned off the ITM ring heaters per Sheilas request
LOG:
10:58 Changed DOF_3_Y OFFSET from 0.6 to 0.3.
11:00 Changed DOF_3_Y OFFSET from 0.3 to 0.75.
11:02 Lockloss, not sure if it was from this change or just the dying diff pwr.
11:41 NLN
11:46 Lockloss ESDX HV tripped
12:48 Headed to EX to investigate ESD HV
13:15 Back
13:56 Turned OFF ITM ring heaters as per Sheila's instructions
15:16 Richard to EX to swap power supplies
15:35 Richard back, didnt need to swap them.