MC2 Metal Build OLVs measured
BOSEMs
s/n 092, OLV 27702.4 (T1)
s/n 043, OLV 22923.7 (T2)
s/n 030, OLV 28098.7 (T3)
s/n 023, OLV 26766.2 (LF)
s/n 086, OLV 27693.4 (RT)
s/n 613, 30169.8 (SIDE) Characterized one
AOSEMs
M2
s/n 307, OLV 24825 (M2 UL)
s/n 474, OLV 24060 (M2 LL)
s/n 439, OLV 24304 (M2 UR)
s/n 305, OLV 25954 (M2 LR)
M3
s/n 207, OLV 24822 (M3 UL)
s/n 311, OLV 23630 (M3 LL)
s/n 446, OLV 26177 (M3 UR)
s/n 188, OLV 16687 (M3 LR)
[Stuart A, Jeff B, Betsy B] Relevant DQ channels needed to be made available for the new x1sushxts05 model. Therefore the x1sushxts05.ini file has been edited to include the following channels (note that the original file was backed-up with the file name x1sushxts05_bak.ini):- X1:SUS-HXTS_M1_OSEMINF_T1_OUT_DQ X1:SUS-HXTS_M1_OSEMINF_T2_OUT_DQ X1:SUS-HXTS_M1_OSEMINF_T3_OUT_DQ X1:SUS-HXTS_M1_OSEMINF_LF_OUT_DQ X1:SUS-HXTS_M1_OSEMINF_RT_OUT_DQ X1:SUS-HXTS_M1_OSEMINF_SD_OUT_DQ X1:SUS-HXTS_M1_DAMP_L_IN1_DQ X1:SUS-HXTS_M1_DAMP_T_IN1_DQ X1:SUS-HXTS_M1_DAMP_V_IN1_DQ X1:SUS-HXTS_M1_DAMP_R_IN1_DQ X1:SUS-HXTS_M1_DAMP_P_IN1_DQ X1:SUS-HXTS_M1_DAMP_Y_IN1_DQ X1:SUS-HXTS_M2_OSEMINF_LL_OUT_DQ X1:SUS-HXTS_M2_OSEMINF_LR_OUT_DQ X1:SUS-HXTS_M2_OSEMINF_UL_OUT_DQ X1:SUS-HXTS_M2_OSEMINF_UR_OUT_DQ X1:SUS-HXTS_M2_WIT_L_DQ X1:SUS-HXTS_M2_WIT_P_DQ X1:SUS-HXTS_M2_WIT_Y_DQ X1:SUS-HXTS_M3_OSEMINF_LL_OUT_DQ X1:SUS-HXTS_M3_OSEMINF_LR_OUT_DQ X1:SUS-HXTS_M3_OSEMINF_UL_OUT_DQ X1:SUS-HXTS_M3_OSEMINF_UR_OUT_DQ X1:SUS-HXTS_M3_OSEMWIT_L_DQ X1:SUS-HXTS_M3_OSEMWIT_P_DQ X1:SUS-HXTS_M3_OSEMWIT_Y_DQ The framebuilder was restarted using the following commands:- telnet tripleteststand 8087 shutdown Now that all the above channels are available, it should enable transfer functions and power spectra to be taken.